Body: Council Type: Document Meeting: Committee Date: 2022 Collection: Agenda Attachments Municipality: Frontenac County
[View Document (PDF)](/docs/frontenac-county/Item Attachments/Agenda Item/2022/October/Mr. Noah Greer , Township of Central Frontenac, will provide the Committee with an overview of the Olden & Hinchinbrooke Shop Upgrades./Hinchinbrooke Shop Drawings.pdf)
Document Text
TEL 613 531-7873. CEL 613 561-3428 FAX 613 531-0602
31 HILLENDALE AVE. KINGSTON, ONTARIO K7M 1S2
COPYRIGHT THIS DRAWING AND DESIGN ARE THE COPYRIGHT PROPERTY OF E. R. TROUGHT DESIGN SHALL AND NOT BE COPIED, REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER.
EXISTING EAST ELEVATION 1/4" = 1’-0"
No.
DATE
DESCRIPTION
BY
REVISIONS
D
OFESSIONA L PR
EER GIN EN
CE
100121350
PR
8/17/2022
O
V
IN
IO
E. R. TROUGHT
R
SCALE:
LIC E N
1 A1
CE
OF
ON
TA
DRAWINGS MUST NOT BE SCALED
CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND SHALL REPORT ANY DISCREPANCY TO THE ENGINEER BEFORE PROCEEDING WITH ANY WORK.
REUSE EXISTING DOOR IN NEW ADDITION
THESE PLANS WERE DESIGNED IN ACCORDANCE WITH THE ONTARIO BUILDING CODE. THESE PLANS FORM THE BASIS FOR PERMIT ISSUANCE AND ANY DEVIATIONS FROM THESE PLANS AND DETAILS, INCLUDING THE VENTILATION SYSTEM, HEATING SYSTEM, WOODSTOVE, FIREPLACES, DECKS, BALCONIES AND FINISHED BASEMENTS, WILL REQUIRE A REVISED DRAWING AND CLEARANCE BY THE BUILDING DEPARTMENT.
36
PROJECT:
PROPOSED ADDITION TO HICHINBROOKE SHOP (CENTRAL FRONTENAC TOWNSHIP)
2 A1
EXISTING NORTH ELEVATION SCALE:
LOCATION :
9439 ROAD 38, GODFREY, ON
1/4" = 1’-0" FOR:
NOAH GREER (CENTRAL FRONTENAC TOWNSHIP) DRAWING:
EXISTING ELEVATIONS
REVIEWED BY:
SCALE
DEPT.
NAME
ARCH.
CD
STR.
ET
MEC.
ET
DATE:
ELE . JOB #:
CD
Wednesday, August 17, 2022
22235
1/4" = 1’-0"
SHEET: 1 of 4
DRAWING No.
A1 22235
TEL 613 531-7873. CEL 613 561-3428 FAX 613 531-0602
31 HILLENDALE AVE. KINGSTON, ONTARIO K7M 1S2
COPYRIGHT THIS DRAWING AND DESIGN ARE THE COPYRIGHT PROPERTY OF E. R. TROUGHT DESIGN SHALL AND NOT BE COPIED, REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER.
EX. GARAGE
EX. WASH RM
No.
DATE
DESCRIPTION
BY
REVISIONS
CE
E. R. TROUGHT 100121350
PR
8/17/2022 V
O
RELOCATE EXIST DOOR INTO NEW ADDITION
IN
IO
LIC E N
D
OFESSIONA L PR
EER GIN EN
EX. STAFF ROOM
R
LOCATION OF NEW ADDITION
+/- 32’-11 3/4"
10’-8"
EX. STORAGE
CE
OF
ON
TA
DRAWINGS MUST NOT BE SCALED
36
2’-11 1/2"
36
CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND SHALL REPORT ANY DISCREPANCY TO THE ENGINEER BEFORE PROCEEDING WITH ANY WORK. THESE PLANS WERE DESIGNED IN ACCORDANCE WITH THE ONTARIO BUILDING CODE. THESE PLANS FORM THE BASIS FOR PERMIT ISSUANCE AND ANY DEVIATIONS FROM THESE PLANS AND DETAILS, INCLUDING THE VENTILATION SYSTEM, HEATING SYSTEM, WOODSTOVE, FIREPLACES, DECKS, BALCONIES AND FINISHED BASEMENTS, WILL REQUIRE A REVISED DRAWING AND CLEARANCE BY THE BUILDING DEPARTMENT.
EX. OFFICE PROJECT:
PROPOSED ADDITION TO HICHINBROOKE SHOP (CENTRAL FRONTENAC TOWNSHIP) 8’-5 1/2"
14’-6"
LOCATION :
17’-4 3/4"
9439 ROAD 38, GODFREY, ON 40’-4 1/4"
14' 54’-4 1/4"
FOR:
NOAH GREER (CENTRAL FRONTENAC TOWNSHIP) DRAWING:
EXISTING FLOOR PLAN
REVIEWED BY:
SCALE
DEPT.
NAME
ARCH.
CD
STR.
ET
MEC.
ET
DATE:
ELE . JOB #:
CD
Wednesday, August 17, 2022
22235
1/4" = 1’-0"
SHEET: 2 of 4
DRAWING No.
A2 22235
TEL 613 531-7873. CEL 613 561-3428 FAX 613 531-0602
31 HILLENDALE AVE. KINGSTON, ONTARIO K7M 1S2
NOTE:
- ALL ROOF & WALL MOLDINGS/TRIM, COLOR & BRAND TO BE CONFIRMED BY CONTRACTOR AND HOME OWNER
- ALL WINDOW & DOOR SIZES, MOLDINGS, COLOR TO BE CONFIRMED BY CONTRACTOR & HOME OWNER
- ALL EXTERIOR SIDING COLOR & BRAND TO BE CONFIRMED BY CONTRACTOR & HOME OWNER
- ALL METAL ROOFING COLOR, STYLE TYPE & BRAND TO BE CONFIRMED BY CONTRACTOR & HOME OWNER
- ALL EAVESTROUGH & FASCIA COLOR AND MATERIAL TO BE CONFIRMED BY CONTRACTOR & HOME OWNER
COPYRIGHT THIS DRAWING AND DESIGN ARE THE COPYRIGHT PROPERTY OF E. R. TROUGHT DESIGN SHALL AND NOT BE COPIED, REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER.
LOCATION OF ADDITION STEEL ROOFING TO MATCH EXISTING (TYP) ALUMINUM FASCIA & SOFFIT C/W EAVESTROUGH (TYP) STEEL SIDING TO MATCH EXISTING (TYP) 36
FINISHED GRADE
PROPOSED EAST ELEVATION 1/4" = 1’-0"
LOCATION OF ADDITION
No.
DATE
DESCRIPTION
BY
REVISIONS
72X36
E. R. TROUGHT 100121350
8/17/2022
O
V
PROPOSED NORTH ELEVATION SCALE:
IN
IO
PR
2 A3
EER GIN EN
D
OFESSIONA L PR
R
72X36
CE
SCALE:
LIC E N
1 A3
CE
OF
ON
TA
DRAWINGS MUST NOT BE SCALED
CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND SHALL REPORT ANY DISCREPANCY TO THE ENGINEER BEFORE PROCEEDING WITH ANY WORK.
1/4" = 1’-0"
THESE PLANS WERE DESIGNED IN ACCORDANCE WITH THE ONTARIO BUILDING CODE. THESE PLANS FORM THE BASIS FOR PERMIT ISSUANCE AND ANY DEVIATIONS FROM THESE PLANS AND DETAILS, INCLUDING THE VENTILATION SYSTEM, HEATING SYSTEM, WOODSTOVE, FIREPLACES, DECKS, BALCONIES AND FINISHED BASEMENTS, WILL REQUIRE A REVISED DRAWING AND CLEARANCE BY THE BUILDING DEPARTMENT.
PROJECT:
PROPOSED ADDITION TO HICHINBROOKE SHOP (CENTRAL FRONTENAC TOWNSHIP) LOCATION :
9439 ROAD 38, GODFREY, ON FOR:
NOAH GREER (CENTRAL FRONTENAC TOWNSHIP) DRAWING:
PROPOSED ELEVATIONS
REVIEWED BY:
SCALE
DEPT.
NAME
ARCH.
CD
STR.
ET
MEC.
ET
DATE:
ELE . JOB #:
CD
Wednesday, August 17, 2022
22235
1/4" = 1’-0"
SHEET: 3 of 4
DRAWING No.
A3 22235
LINE OF GRADE BEAM (TYP)
COPYRIGHT THIS DRAWING AND DESIGN ARE THE COPYRIGHT PROPERTY OF E. R. TROUGHT DESIGN SHALL AND NOT BE COPIED, REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN CONSENT OF THE ENGINEER.
1’ (TYP)
NEW EXTERIOR STUD WALL (TYP) -STEEL SIDING
- TYPAR HOUSE WRAP -1/2" OSB SHEATHING -2X6 STUD WALL @ 16" O/C -R24 BATT INSULATION -6 MIL PLY VAPOR BARRIER -1/2" GYPSUM BOARD
10’-8"
EX. STORAGE
9’-4 3/4"
(2) 2X10 LINTEL
EX. WASH RM
72X36
EX. WASH RM
NEW LOAD-BEARING STUD WALL SUPPORTING ROOF @ EXISTING BUILDING -2X6 STUD WALL @ 16" O/C -HORIZONTAL BLOCKING @ 4’ O/C 1/2" GYPSUM BOARD
8’-2 3/8" (TYP)
SUPPLY NEW PLUMBING FIXTURES TO REPLACE ONLY ONES
1’ (TYP)
14’-10"
+/- 32’-9 3/4"
NEW WINDOW
(2) 2X10 LINTEL
54X36
1/2" CUT FOR CRACK CONTROL (TYP) +/- 32’-9 3/4"
EX. GARAGE
NEW STAFF RM/TRAING ROOM 1 : 12
LINE OF ROOF (TYP)
3
TEL 613 531-7873. CEL 613 561-3428 FAX 613 531-0602
31 HILLENDALE AVE. KINGSTON, ONTARIO K7M 1S2
7’ (TYP)
BY
REVISIONS
1/4" = 1’-0" CE
LIC E N PR
EM
D
E. R. TROUGHT 100121350
8/17/2022 V
O
36 (2) 2X10 LINTEL
OFESSIONA L PR
IN
IO
GRADE BEAM PLAN SCALE:
DESCRIPTION
R
2 A4
DATE
8’-7"
EM
No.
EER GIN EN
NOTE:
- ALL FLOORING AND WALL MATERIALS TO BE CONFIRMED BY OWNER
- ALL DIMENSIONS TO BE CONFIRMED BY CONTRACTOR PRIOR TO STARTING CONSTRUCTION
- NEW PLUMBING FIXTURES TO BE CONFIRMED BY OWNER
- ALL EXISTING ELECTRICAL TO REMAIN
- OWNER TO CONFIRM ALL LIGHT, SWITCH, AND OUTLET LOCATIONS AND COLOR
(2) 2X10 LINTEL
EX. STAFF ROOM
36
RELOCATE EXIST DOOR INTO NEW ADDITION
4 A4 72X36
(2) 2X10 LINTEL
14'
CE
OF
ON
TA
36
DRAWINGS MUST NOT BE SCALED
EX. OFFICE
2’-6"
CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND SHALL REPORT ANY DISCREPANCY TO THE ENGINEER BEFORE PROCEEDING WITH ANY WORK.
11’-6"
8’-5 1/2"
14’-6"
THESE PLANS WERE DESIGNED IN ACCORDANCE WITH THE ONTARIO BUILDING CODE. THESE PLANS FORM THE BASIS FOR PERMIT ISSUANCE AND ANY DEVIATIONS FROM THESE PLANS AND DETAILS, INCLUDING THE VENTILATION SYSTEM, HEATING SYSTEM, WOODSTOVE, FIREPLACES, DECKS, BALCONIES AND FINISHED BASEMENTS, WILL REQUIRE A REVISED DRAWING AND CLEARANCE BY THE BUILDING DEPARTMENT.
ROOF CONSTRUCTION (TYP): -STEEL ROOFING INSTALLED AS PER MANUFACTURE SPECIFICATIONS ICE & WATER SHIELD 3’ UP FROM EAVES -1/2" PLYWOOD W/ ‘H’ CLIPS @ 24" O/C -2X10 ROOF RAFTERS @ 24" O/C -5 1/2" R33 MEDIUM DENSITY SPRAY FOAM INSULATION -RESILIENT CHANNEL @ 16" O/C -1/2" GYPSUM BOARD
14’
17’-4 3/4" 40’-4 1/4"
PROJECT:
PROPOSED FLOOR PLAN 1/4" = 1’-0" MAKE
1/2" ØX6" ANCHOR BOLT @ 5’ O/C R-7.5 1.5" SM RIGID INSULATION
2 1/2"
FINISHED GRADE
GARRISON
SYMBOL
DESCRIPTION
EM
5"
6X6X6ga REINFORCING MESH
FIRE EXTINGUISHER
MODEL
SYMBOL
GENERAL PURPOSE
FE
EXIT SIGN WITH EMERGENCY LIGHTING - EMERGILITE PICTOGRAM - MODEL ECSC-ELEDWR-RT DOUBLE HEAD EMERGENCY LIGHTING - IDEAL SECURITY INC. - MODEL # SK636
NOTE: EAVE PROTECTION TO EXTEND FROM THE EDGE OF THE ROOF, 36" UP THE SLOPE BUT NOT LESS THAN12" BEYOND THE INTERIOR FACE OF THE EXTERIOR WALL
LOCATION :
9439 ROAD 38, GODFREY, ON
LOAD-BEARING WALL CONSTRUCTION: -2X6 STUD WALL @ 16" O/C -HORIZONTAL BLOCKING @ 4’ O/C -1/2" GYPSUM BOARD
EXTERIOR WALL CONSTRUCTION: -STEEL SIDING -TYPAR HOUSE WRAP -1/2" OSB -2X6 STUD WALL @ 16" O/C -R- 24 BATT INSULATION -6 MIL POLY VAPOR BARRIER -1/2" GYPSUM BOARD
SYMBOL
110V Receptacles: Duplex, GFI
GFI: Ground Fault Receptacles
3
R-10 2" OWENS CORNING FOAMULAR 600 HIGH DENSITY EXTRUDED POLYSTYRENE RIGID INSULATION
2"
1/2" ANCHOR BOLT 5’ O/C
3-Way Switch Ceiling Mounted Light Fixtures: Surface/Pendant
2"
1'
3 A4
1'
1'
GRADE BEAM DETAIL SCALE:
3/4" = 1’-0"
4 A4
ADDITION SECTION SCALE:
FOR:
NOAH GREER (CENTRAL FRONTENAC TOWNSHIP) DRAWING:
PROPOSED FLOOR PLAN ADDITION SECTION
2X6 SILL PLATE C/W SILL GASKET
Single Pole Switch
6" COMPACTED GRANULAR ‘A’ (2) 15M CONTINUOUS BARS, OVERLAP SPLICES 12"
DESCRIPTION
6"
R-10 2" SM RIGID INSULATION
CONCRETE SLAB FLOOR:
- 5" CONCRETE 32 MPa CONCRETE
- 2" R10 SM RIGID INSULATION
- 6X6X6GA REINFORCING MESH
- 6" COMPACTED GRANULAR ‘A
2"
5° 13
2"
2"
1’
2"
6"
1’-6"
SINGLE HEAD EMERGENCY LIGHTING - IDEAL SECURITY INC. - MODEL # SK638
ELECTRICAL LEGEND
PROPOSED ADDITION TO HICHINBROOKE SHOP (CENTRAL FRONTENAC TOWNSHIP)
8’-1 1/8"
SCALE:
ALUMINUM FASCIA AND SOFFIT COMPLETE W/ EAVESTROUGH (TYP)
3/8" = 1’-0"
1'
1’-6"
1 A4
REVIEWED BY:
SCALE
DEPT.
NAME
ARCH.
CD
STR.
ET
MEC.
ET
DATE:
ELE . JOB #:
CD
Wednesday, August 17, 2022
22235
AS SHOWN
SHEET: 4 of 4
DRAWING No.
A4 22235